RCCBO Ex9CBL

Mã sản phẩm : ex9cbl

Modular combined residual current devices with circuit breaker, with a breaking capacity of 10 kA for Ex9CBL-H Series and 6 kA for Ex9CBL-N Series. The devices meet the requirements of the standard IEC / EN 61009. These protectors are intended for household and industrial applications. They provide 50 per cent space economy compared to separate residual current device and separate circuit breaker.

0
Số lượng:

    Modular combined residual current devices with circuit breaker, with a breaking capacity of 10 kA for Ex9CBL-H Series and 6 kA for Ex9CBL-N Series. The devices meet the requirements of the standard IEC / EN 61009. These protectors are intended for household and industrial applications. They provide 50 per cent space economy compared to separate residual current device and separate circuit breaker.

    Ex9CBL Series is provided with nominal currents ranging from 6 to 40 A, and B and C breaker tripping characteristics. The device’s parameters are determined by the nominal residual current of 30, 100 and 300 mA, and AC and A sensitivity. Due to their tripping capability of 10 kA (-H) and 6 kA (-N), they are intended for all applications, including the most demanding ones.   

    • Meet requirements of IEC / EN 61009
    • Rated breaking capacity Icn 10 kA
    • 1+N-pole version
    • Rated residual current 30, 100, 300 mA
    • Rated currents up to 40 A
    • Rated operational voltage 230 V AC
    • Tripping characteristics of circuit breaker B and C
    • AC and A type of RCD
    • 2-module width
    _________________
    Download Datasheet

Sản phẩm liên quan

0

MCB Ex9B125

Aptomat EX9B125 đa dụng, tiêu chuẩn EN 60898, dòng định mức từ 1 đến 63A, dòng cắt 25kA

0

MCB Ex9PN

Aptomat Ex9PN, số cức 1P+N, dòng định mức 1-40A, dòng cắt 6kA

0

Accessories for Ex9B/Ex9PN

Accessories is designed in the way to be possible to combine different types with one installation device. It can be used up to two releases plus up to three units of auxiliary or signal contacts (two units in case of AX3122 with two pairs of contacts) plus one unit of RCD-block (only for Ex9B MCBs).

0

RCCB Ex9CL

Modular residual current devices Ex9CL-H and Ex9CL-N in two or four-pole design. Technology is based on the classical principle of permanent magnet and electromagnetic armature, providing full voltage independence of protective functions. Circuit breakers comply with the requirements of the standards IEC/EN 61008-1.